Place of Origin:
China
Brand Name:
G-Tech
Certification:
CCC;CE;Rohs;ISO
Model Number:
PT
Automatically transferred to battery mode when input over voltage or under voltage
Output overload and short circuit protection
can be connected to external battery for longer power supply
Powerful charging current for high-capacity battery.
Rank Mountable type
Product Introduction
This series UPS applies CPU integrated control technology, which allows UPS to response promptly and accurately when power outage, high or low voltage, surge, transient or spike occurs while its surge protection port provides protection for special external devices, such as printers and so on. It possesses automatic startup function, automatic voltage regulation function and a wide range of input voltage, so it is applicable to all kinds of electric power enviroment. In addition, its design is humanized and elegant with LED or LCD display, those are two alternatives.
Model # | RT-3KS | ||||||||||
Rated Power | 3000KVA/2700W | ||||||||||
Display | LCD | ||||||||||
INPUT | |||||||||||
Voltage Range | Transfer | 160VAC±5% or 300VAC±5% | |||||||||
No-load | 110VAC±5% or 300VAC±5% | ||||||||||
Frequency | 40-70Hz | ||||||||||
OUTPUT | |||||||||||
Output Voltage | 220VAC | ||||||||||
Frequency |
47-53Hz or 57-63Hz(Synchronized Range) | ||||||||||
50Hz±0.25Hz or 60Hz±0.3Hz(Battery Mode) | |||||||||||
Wave Form | Pure Sine Wave | ||||||||||
BATTERY | |||||||||||
QTY &capacity of Battery |
Battery Pack 6pcs*12V/7AH
|
||||||||||
External Battery Norminal DC | ---------------------------------------------- | ||||||||||
Transfer Time | 0ms | ||||||||||
Overload Capacity |
105%-110%:Only a warning 110%-130%:UPS shut down after 1min at battery mode or transfer to bypass when the untility is normal >130%:UPS shut down immediately at battery mode or transfer to bypass when the untility is normal |
||||||||||
Interface | 220V:RJ45/11+RS232,USB or SNMP Solt selectable (optional) | ||||||||||
Protection | |||||||||||
Protections |
Auto re-start when AC recovers; Slient Set-up; Automatical Charging(Offline Charging); Battery Low voltage protection; Over-load and short circut protection |
||||||||||
PHYSICAL | |||||||||||
Unit Dimension(mm) | 482*87*420 | ||||||||||
Gross Weight | 12.7 | ||||||||||
Net weight(kg) | 9.3 | ||||||||||
Power Factor:0.9 | |||||||||||
Certificate | CE Approved | ||||||||||
EMC Directive | EN62040-2,EN61000-3-2 | ||||||||||
LVD Directive | EN62040-1 |